Abstract:A pilot plant operation at the Savannah River Site will remove 90Sr, 137Cs, and transuranics from a high-level liquid waste stream prior to encapsulation in a Saltstone Facility. Monitors are required to determine the concentrations of all radionuclides, including transuranics, in real-time on this processed waste stream. A neutron counter used to measure the concentration of each actinide isotope present in the stream is described. The neutron counter assembly consists of nested annular layers of shielding, reflectors, detectors, and moderators. On-line, live-time system control and calibration is provided by a time-tagged neutron source embedded in the moderator assembly.