Abstract: | The power flowing through the isolators and into the supporting foundation of a machine is examined by approximating the driving point frequency response function of the foundation. One and two stage isolation of machines with internal force or velocity sources is considered. Two stage isolation is superior to single stage isolation in reducing power flow in those circumstances where the excitation spectra do not cover the two resonances of the system. |
| |