首页 | 本学科首页   官方微博 | 高级检索  
     


On-line model-based fault detection and isolation for PEM fuel cell stack systems
Affiliation:1. Interdisciplinary Centre for Security Reliability and Trust (SnT), University of Luxembourg, 4 rue Alphonse Weicker, L-2721, Luxembourg;2. Automatic Control Department, Universitat Politècnica de Catalunya (UPC), Rambla Sant Nebridi 10, 08222 Terrassa, Spain
Abstract:Efficient and reliable operation of Polymer Electrolyte Membrane (PEM) fuel cells are key requirements for their successful commercialization and application. The use of diagnostic techniques enables the achievement of these requirements. This paper focuses on model-based fault detection and isolation (FDI) for PEM fuel cell stack systems. The work consists in designing and selecting a subset of consistency relations such that a set of predefined faults can be detected and isolated. Despite a nonlinear model of the PEM fuel cell stack system will be used, consistency relations that are easily implemented by a variable back substitution method will be selected. The paper also shows the significance of structural models to solve diagnosis issues in complex systems.
Keywords:Fault diagnosis  Consistency relation  Residual generation  Fuel cell system
本文献已被 ScienceDirect 等数据库收录!