首页 | 本学科首页   官方微博 | 高级检索  
     

聚对氨基苯磺酸修饰电极对桑枝中桑色素的灵敏测定
引用本文:姚淑艳,王宗花,张菲菲,夏建飞,夏延致,李延辉. 聚对氨基苯磺酸修饰电极对桑枝中桑色素的灵敏测定[J]. 分析测试学报, 2012, 31(1): 100-103
作者姓名:姚淑艳  王宗花  张菲菲  夏建飞  夏延致  李延辉
作者单位:青岛大学纤维新材料与现代纺织实验室,国家重点实验室培育基地,化学化工与环境学院,山东青岛266071
基金项目:国家自然科学基金资助项目(20975056,50802045);青岛市科技计划基础研究项目(091330jch);NSFC-JSPS中日合作与交流项目(21111140014);山东省泰山学者资助项目(TS20070711)
摘    要:采用电聚合的方法制备了聚对氨基苯磺酸(PABSA)修饰电极,以循环伏安法和差分脉冲伏安法研究了桑色素在该修饰电极上的电化学行为。PABSA和黄酮类药物桑色素的π-π共轭作用使得桑色素在该修饰电极上产生的氧化峰更加灵敏。实验发现,在pH 7.0的磷酸盐缓冲介质中,桑色素在0.214 V处产生灵敏的氧化峰。在优化实验条件下,采用差分脉冲伏安法对桑色素进行定量测定,桑色素的氧化峰电流与其浓度呈良好的线性关系,线性范围为5.0×10-7~1.0×10-3 mol/L,检出限为1.0×10-7 mol/L。将该修饰电极用于桑枝生物样品中桑色素含量的测定,结果满意。该方法具有灵敏度高、重现性好的特点,且该修饰电极稳定性高,可重复使用。

关 键 词:聚对氨基苯磺酸;修饰电极;桑色素;电化学

Sensitive Determination of Morin in Ramulus Mori on the Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode
YAO Shu-yan , WANG Zong-hua , ZHANG Fei-fei , XIA Jian-fei , XIA Yan-zhi , LI Yan-hui. Sensitive Determination of Morin in Ramulus Mori on the Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode[J]. Journal of Instrumental Analysis, 2012, 31(1): 100-103
Authors:YAO Shu-yan    WANG Zong-hua    ZHANG Fei-fei    XIA Jian-fei    XIA Yan-zhi    LI Yan-hui
Affiliation:(Laboratory of Fiber Materials and Modern Textile,The Growing Base for State Key Laboratory,College of Chemical and Environment Engineering,Qingdao University,Qingdao 266071,China)
Abstract:A novel PABSA modified glassy carbon electrode(PABSA/GCE) was fabricated by electropolymerizing PABSA on the surface of GC electrode.Morin can effectively accumulate on the electrode for the π-π stacking reaction between the aromatic rings of morin and the dimers of PABSA and cause an increased anodic peak signal.Based on this,a method was developed for the determination of morin.The electrochemical behaviors of morin on the modified electrode were investigated using cyclic voltammetry(CV) and differential pulse voltammetry(DPV).The results showed that,in pH 7.0 PBS,morin generated a sensitive anodic peak at 0.214 V.Under the optimized conditions,DPV was used for detecting morin.The calibration curve was linear in the range of 5.0×10-7-1.0×10-3 mol/L,with a detection limit of 1.0×10-7 mol/L.The modified electrode,with the advantages of good stability,repeatability and wide linear range,was successfully applied in the determination of morin content in ramulus mori.
Keywords:poly(p-aminobenzene sulfonic acid)  modified electrode  morin  electrochemistry
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《分析测试学报》浏览原始摘要信息
点击此处可从《分析测试学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号