首页 | 本学科首页   官方微博 | 高级检索  
     


A novel ultrasonic strain gauge for single-sided measurement of a local 3D strain field
Authors:Mathias Kersemans  Klaas Allaer  Wim Van Paepegem  Koen Van Den Abeele  Lincy Pyl  Filip Zastavnik  Hugo Sol  Joris Degrieck
Affiliation:1. Department of Materials Science and Engineering, Ghent University, Technologiepark-Zwijnaarde 903, 9052, Zwijnaarde, Belgium
2. Department of Physics, Catholic University of Leuven - KULAK, Etienne-Sabbelaan 52, 8500, Kortrijk, Belgium
3. Department Mechanics of Materials and Constructions, Vrije Universiteit Brussel, Pleinlaan 2, 1050, Brussels, Belgium
Abstract:A novel method is introduced for the measurement of a 3D strain field by exploiting the interaction between ultrasound waves and geometrical characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incident pulsed waves in frequency domain provides a measure of the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed ultrasonic strain gauge yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are needless. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2 % up to 35 %. The ultrasonically measured strains have been validated with various other strain measurement techniques, including manual micrometer, longitudinal and transverse mechanical extensometer and optical mono- and stereovision digital image correlation. Good agreement has been obtained between the ultrasonically determined strain values and the results of the conventional methods. As the ultrasonic strain gauge provides all three normal strain field components, it has been employed for the extraction of Lankford ratios at different applied longitudinal plastic strain levels, revealing a strain dependent plastic anisotropy of the investigated DC06 steel sheet.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号