High-performance liquid chromatographic determination of amitriptyline and its main metabolites using a silica column with reversed-phase eluent. Application in mice.
Authors:F Coudore  D Ardid  A Eschalier  J Lavarenne  J Fialip
Institution:Laboratoire de Pharmacologie Médicale, INSERM U195, Faculté de Médecine, Clermont-Ferrand, France.
Abstract:A method was developed for the assay of amitriptyline, amitriptyline N-oxide, nortriptyline, desmethylnortriptyline and E (trans) and Z (cis) isomers of 10-hydroxyamitriptyline and of 10-hydroxynortriptyline in plasma and brain of animals, using high-performance liquid chromatography with ultraviolet detection (254 nm). Single extraction was performed at pH 10.5 from 0.25 ml of plasma or 1 ml of brain mixture. Chromatographic separations were achieved with a silica column and an aqueous methanol mobile phase containing ammonia. This procedure offers high sensitivity (8-10 ng/ml), high linearity (r > 0.99) and acceptable precision (coefficient of variation < or = 13.3%). The method was used to determine levels of amitriptyline and its major metabolites in mice 30 min after a single intraperitoneal administration of amitriptyline (20 mg/kg).