首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of low concentrations of iodine-131 in fast-reactor coolant systems
Authors:Ware A R  Oldham G  Bibby D M
Affiliation:Department of Chemistry University of Technology Loughborough Leicestershire, U.K.
Abstract:A method has been devised for the determination of iodine-131 in the presence of mixed fission products in reactor coolants, by oxidation to elemental iodine followed by sublimation on to copper gauzes. The method reduces to a minimum contamination of the copper gauzes by ruthenium-103 and ruthenium-106 and eliminates contamination due to technetium-99 and caesium-137. It is possible to determine 10(2)cpm ml from iodine-131 in a total count of 2 x 10(6)cpm ml of fission products, with an accuracy of +/- 3%. The only activity collected on the copper gauzes was iodine-131 (62% collection efficiency) and ruthenium-103 (0.005% of total activity) which gave comparable count rates. The activity of these two isotopes was separated by single-channel gamma analysis.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号