首页 | 本学科首页   官方微博 | 高级检索  
     


Flow-injection spectrophotometric determination of palladium in catalysts and dental alloys with 2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropyl-amino)aniline
Authors:Tadao Sakai  Norko Ohno
Affiliation:Department of Chemistry, Asahi University, 1851 Hozumi, Hozumi-cho, Gifu 501-02 Japan
Abstract:2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)aniline rapidly forms a water-soluble complex with palladium in an acetate-buffered medium at pH 3.2.The molar absorptivity of the complex is 9.84×104l mol?1 at 612 nm. The calibration graph is linear over the range of 10–100 μg l?1 palladium; the detection limit is 2 μg l?1 and the relative standard deviation is 0.6% for 100 μg l?1 palladium. The sample throughput is 50 h?1. Divalent transition metals (Fe, Ni, Co) do not interfere at levels from 2 to 10 mg l?1. Interference from copper is prevented by adding 10?3 M EDTA solution to the carrier stream. Palladium in solutions of catalysts and dental alloys can be determined selectively, sensitively and rapidly.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号