首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental Measurements on the Current Balance at the Cathode of a Cylindrical Hollow Cathode Glow Discharge
Authors:H. Helm
Abstract:The contribution of positive ions, photons and metastable particles to the secondary emission of electrons from the cathode of an argon glow discharge with cylindrical cathode is measured by sampling the plasma species through a small orifice in the cathode wall and analyzing them in a high vacuum region. Additional experiments are made with a second apparatus which enables the sampling fo plasma species from the negative glow and the dark space. The paper describes the experimental techniques used in both cases and presents estimates on the validity of the results obtained. The positive ions are found to be the dominant contribution to the discharge current at the cathode. The secondary emission of electrons is — in decreasing order of importance — due to impact fo singly charged ions, doubly charged ions and metastable atoms.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏