Correlation between time functions of sound pressure, masking, and OAE suppression
Authors:E Zwicker  A Scherer
Abstract:Periodic sound-pressure time functions with frequency components below 50 Hz were used to measure within their period (a) the temporal course of masking, called a masking-period pattern (MPP), and (b) the temporal course of suppression of delayed evoked otoacoustic emissions, called a suppression-period pattern (SPP). Three different time functions were used: an alternating Gaussian impulse, its first integral, and its second integral. In each case, the course of the SPP is a mirror image of that of the MPP: Small masking corresponds to small suppression, while strong masking coincides with almost total suppression. Since otoacoustic emissions are assumed to have their origin in the inner ear, it can be argued that simultaneous masking, an effect including central processing, is very strongly based on peripheral processes located in the cochlea. Both MPP and SPP are closely related to the second derivative of the sound-pressure time function.