用同步辐射源建立紫外及真空紫外光谱区光谱辐射度基准的研究
引用本文:熊利民,刘金元,李平,薛凤仪,杨永刚,李大欣,陈赤,周洪军,霍同林.用同步辐射源建立紫外及真空紫外光谱区光谱辐射度基准的研究[J].光学学报,2006,26(4):47-550.
作者姓名:熊利民  刘金元  李平  薛凤仪  杨永刚  李大欣  陈赤  周洪军  霍同林
作者单位:1. 中国计量科学研究院光学处,北京,100013
2. 中国科学技术大学国家同步辐射实验室,合肥,230039
摘    要:叙述了中国科学技术大学国家同步辐射实验室800 MeV电子储存环同步辐射的特性及作为光谱辐射亮度基准的原理和方法,精确计算出同步辐射光源光谱功率空间分布,并在计量学上将同步辐射“经典”理论与标定氘灯光谱辐射亮度结合起来,对“同步辐射作为标准源进行光谱辐射功率计量”进行深入的研究。介绍了国家同步辐射实验室计量光束线站的装置,该装置利用同步辐射波长范围宽、亮度高、辐射特性可精确计算等特点,可用于标定传递标准氘灯的光谱辐射亮度(115~350 nm),并进行了不确定度分析。并与德国技术物理研究院(PTB)标定的氘灯光谱辐射亮度进行比较,两者符合。

关 键 词:计量学  紫外和真空紫外光谱辐射度基准  同步辐射  氘灯
文章编号:0253-2239(2006)04-0547-4
收稿时间:2005-04-28
修稿时间:2005-08-03

Ultraviolet and Vacuum Ultraviolet Spectral Radiance Standard with Synchrotron Radiation Source
Xiong Limin,Liu Jinyuan,Li Ping,Xue Fengyi,Yang Yonggang,Li Daxin,Chen Chi,Zhou Hongjun,Huo Tonglin.Ultraviolet and Vacuum Ultraviolet Spectral Radiance Standard with Synchrotron Radiation Source[J].Acta Optica Sinica,2006,26(4):47-550.
Authors:Xiong Limin  Liu Jinyuan  Li Ping  Xue Fengyi  Yang Yonggang  Li Daxin  Chen Chi  Zhou Hongjun  Huo Tonglin
Institution:1. Optical Division, National Institute of Metrology, Beijing 100013 ;2. National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230039
Abstract:The characteristics of the 800 MeV electron storage ring of National Synchrotron Radiation Laboratory (NSRL, located in University of Science and Technology of China) are introduced. The theory and the method used to build spectral radiance standard with the synchrotron radiation are presented, and the spatial spectral power distribution of the synchrotron radiation source is calculated accurately. The classical theory of the synchrotron radiation and the spectral radiance luminance calibration of the deuterium lamp are related, and the spectral radiance power metrology using the synchrotron radiation as the standard source is studied extensively. The metrological beamline of NSRL with wide wave range, high luminance and accurately calculated radiance properties is presented, which can be used to calibrate the spectral radiance luminance of the deuterium lamp (1115~350 nm), and the uncertainty is analyzed. The calibration result is consistent with that of physical research institute (PTB) of Deutschland.
Keywords:metrology  ultraviolet(UV) and vacuum ultraviolet (VUV) spectral radiance standard  synchrotron radiation  deuterium lamp