首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Indirect spectrophotometric determination of fluoride using the ternary system: Thorium-chrome azurol S-cetyltrimethylammonium
Authors:Łucja Lenarczyk  Zygmunt Marczenko  Maciej Jarosz
Institution:(1) Department of Analytical Chemistry, Technical University, Warsaw, Poland
Abstract:Summary The conditions for the reactions of fluoride with the ternary Th-CAS-CTA/CP/zeph and Th-ECR-CTA complexes have been examined, and a new, sensitive and precise method based on the Th-CAS-CTA-F system developed for the indirect determination of fluoride. The molar absorptivity of the method is extremely high —10.0× 104l·mole–1·cm–1 at 635 nm (in the others, frequently used, spectrophotometric methods for determining fluoride, epsi does not exceed 2.7×104, e. g. for the method with Alizarin Complexone —1.4×104 and with zirconium and Eriochrome Cyanine R— 2.7×104). Beer's law is obeyed up to a fluoride concentration up to 0.08mgrg per ml. The precision and accuracy of the method were tested in analysis of tap water.
Indirekte spektrophotometrische Bestimmung von Fluorid mit Hilfe des Systems Thorium-Chromazurol S-Cetyltrimethylammonium
Zusammenfassung Die Bedingungen für die Umsetzung von Fluorid mit den ternären Komplexen Th-CAS-CTA(CP)zeph und Th-ECR-CTA wurden geprüft und eine neue, empfindliche und genaue Methode für die indirekte Fluoridbestimmung ausgearbeitet, die auf dem System Th-CAS-CTA-F beruht. Dessen molare Absorptivität ist sehr groß: 10,0×104l·mol–1·cm–1 bei 635 nm. (Bei den üblichen spektrophotometrischen Methoden zur Fluoridbestimmung ist epsi nicht größer als 2,7×104 bei der Methode mit Zr und Eriochromcyanin bzw. 1,4×104 bei der Methode mit Alizarin-Komplexon). Das Beersche Gesetz gilt bis zu 0,08mgrg Fluorid/ml. Die Genauigkeit des Verfahrens wurde mit Analysen von Leitungswasser geprüft.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号