Development of picosecond time‐resolved X‐ray absorption spectroscopy by high‐repetition‐rate laser pump/X‐ray probe at Beijing Synchrotron Radiation Facility
Authors:Hao Wang  Can Yu  Xu Wei  Zhenhua Gao  Guang-Lei Xu  Da-Rui Sun  Zhenjie Li  Yangfan Zhou  Qiu-Ju Li  Bing-Bing Zhang  Jin-Qiang Xu  Lin Wang  Yan Zhang  Ying-Lei Tan  Ye Tao
Institution:1. Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing100049, People's Republic of China;2. University of Chinese Academy of Sciences, 19B Yuquan Road, Beijing100049, People's Republic of China;3. Accelerator Division, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing100049, People's Republic of China
Abstract:A new setup and commissioning of transient X‐ray absorption spectroscopy are described, based on the high‐repetition‐rate laser pump/X‐ray probe method, at the 1W2B wiggler beamline at the Beijing Synchrotron Radiation Facility. A high‐repetition‐rate and high‐power laser is incorporated into the setup with in‐house‐built avalanche photodiodes as detectors. A simple acquisition scheme was applied to obtain laser‐on and laser‐off signals simultaneously. The capability of picosecond transient X‐ray absorption spectroscopy measurement was demonstrated for a photo‐induced spin‐crossover iron complex in 6 mM solution with 155 kHz repetition rate.
Keywords:laser pump/X‐ray probe  X‐ray absorption spectroscopy  high repetition rate