Accurate AC/DC voltage measurements using electrostatic comparator
Institution:1. School of Mathematical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China;2. Centre for Artificial Intelligence, FEIT, University of Technology Sydney, NSW 2007, Australia;3. Research Center on Fictitious Economy & Data Science, Chinese Academy of Sciences, Beijing 100190, China;4. Key Laboratory of Big Data Mining and Knowledge Management, Chinese Academy of Sciences, Beijing 100190, China;5. Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA;6. School of Computing and Informatics, University of Louisiana at Lafayette, Louisiana, 70503 USA
Abstract:The electrostatic AC-DC voltage comparator for precise voltage measurement in voltage range of 100–1000 V and frequency range of 20–100,000 Hz was designed. The equality of AC and DC voltages transforms into horizontal positioning of the beam, which is registered by two photoelectric transducers. DC voltage was measured by voltage divider, standard cell and low-voltage comparator. The construction, main characteristics, and sources of errors are described. The comparison error has been determined as having the value of 0.003% at the voltage of 100 V and the value of 0.0009% at the voltage of 1000 V.
Keywords:Electrostatic  Voltage comparator  Electrode  Voltage measurement  Electrostatic transducer  Photoelectric transducer