Sensitive quantification of uranium using cloud point extraction coupled with inductively coupled plasma-optical emission spectrometry
Authors:Zeinab F Akl
Institution:1.Nuclear Safeguards and Physical Protection Department,Egyptian Nuclear and Radiological Regulatory Authority,Cairo,Egypt
Abstract:This article reports the utilization of cloud point extraction as a preconcentration strategy prior to U(VI) determination by inductively coupled plasma-optical emission spectrometry. Complexes of U(VI) with Cyanex-301 were preconcentrated into mixed-micellar medium using Triton X-100 and Cetylpyridinium bromide at ambient temperature. Optimal values of parameters impacting the extraction efficiency were determined. The proposed technique has linearity range of 5–200 ng mL?1 with r = 0.99 and detection and quantification limits of 0.57 and 0.85 ng mL?1, respectively. The method has good selectivity for U(VI) over various cations and was successfully applied to U(VI) determination in water samples with satisfactory results.