Mitigating the effects of higher order multipole fields in the magnets of the Accelerator Test Facility 2 at KEK |
| |
Affiliation: | BAI Sha1 P. Bambade 2 WANG Dou1 GAO Jie1 M. Woodley 3 M. Masuzawa 4 1 Institute of High Energy Physics (IHEP, Beijing 100049, China 2 LAL, Univ Paris-Sud, CNRS/IN2P3, Orsay, France 3 SLAC, Menlo Park, California, USA 4 KEK, Tsukuba, Ibaraki, Japan |
| |
Abstract: | The ATF2 project is the final focus system prototype for the ILC and CLIC linear collider projects, with the purpose of reaching a 37nm vertical beam size at the interaction point. In the nanometer beam size regime, higher order multipoles in magnets become a crucial point for consideration. The strength and rotation angle of the ATF2 QEA magnets were reconstructed from the IHEP measurements and compared with the KEK ones to be identical. Based on the study of the skew multipoles sensitivity, we report on the analysis of the possible mitigation of the measured multipoles. A suggestion is given which will benefit the ATF2 present commissioning to reach the goal beam size, and also the reduced β optics in future. |
| |
Keywords: | ATF2 beam size higher order multipoles QEA magnets |
本文献已被 CNKI 等数据库收录! |
| 点击此处可从《中国物理 C》浏览原始摘要信息 |
|
点击此处可从《中国物理 C》下载全文 |
|