Indirect determination of chloride as chromyl chloride by atomic-absorption spectrophotometry
Authors:C González Pérez  J Hernández Méndez  Ma J Fonseca Ruano  A Ma Bernal Melchor
Institution:(1) Department of Analytical Chemistry, Faculty of Chemistry, University of Salamanca, Spain
Abstract:Summary A method for the determination of chloride in aqueous solution by atomic-absorption Spectrophotometry is described. The chloride is converted into chromyl chloride, which is extracted into carbon tetrachloride and subsequently back-extracted and determined in a solution buffered with NH4H2PO4/(NH4)2HPO4. Calibration plots of the atomic absorption of the aqueous back-extracted phase at the chromium 425.4 nm resonance line are linear in the range 5–270mgrg of chloride. The calibration graph can be obtained directly with aqueous solutions of Cr(VI). The proposed method can be applied directly to mineral and medicinal water samples.
Indirekte AAS-Bestimmung von Chlorid als Chromylchlorid
Zusammenfassung Eine Methode zur Bestimmung von Chlorid durch Atom-Absorptions-Spektroskopie wurde entwickelt, deren Basis die Bildung von Chromylchlorid, dessen Extraktion mit Cl4C und die anschließende Bestimmung des rückextrahierten Chroms in einer Lösung von NH4H2PO4/(NH4)2HPO4 ist. Das lineare Verhältnis zwischen Absorbanz und Chromkonzentration ermöglicht die Bestimmung des Chlorids im Bereich 5–270mgrg; zur direkten Eichung dienten wäßrige Lösungen von Chrom(VI). Die vorgeschlagene Methode wurde für die Chlorid-Bestimmung in Mineral-und Medizinalwasser benutzt.