首页 | 本学科首页   官方微博 | 高级检索  
     检索      

固相萃取-超高效液相色谱分离测定洗涤用品中4种荧光增白剂
引用本文:冼燕萍,郭新东,罗海英,吴玉銮,陈意光,罗东辉,吴文海.固相萃取-超高效液相色谱分离测定洗涤用品中4种荧光增白剂[J].色谱,2013,31(2):162-169.
作者姓名:冼燕萍  郭新东  罗海英  吴玉銮  陈意光  罗东辉  吴文海
作者单位:广州市质量监督检测研究院 国家化妆品质量监督检验中心(广州), 广东 广州 510110
基金项目:国家质检总局科技项目(2009QK325)
摘    要:建立了固相萃取净化结合超高效液相色谱-二极管阵列检测器(UPLC-DAD)同时检测洗衣液、洗衣粉等洗涤用品中荧光增白剂351、85、28和71的分析方法。样品经2%(体积分数)甲酸水溶液-甲醇提取,经WAX固相萃取小柱净化后,采用Phenomenex Synergi Max-RP色谱柱(150 mm×2.0 mm),以乙腈-10 mmol/L乙酸铵为流动相实现待测物(包括顺式和反式异构体)的良好分离,以二极管阵列检测器检测,结合保留时间和光谱图定性,以标准曲线定量。结果表明,4种荧光增白剂在0.05~180 mg/L范围内线性关系良好,相关系数均大于0.9993;方法定量限(S/N=10)为1.5~15 mg/kg;添加水平为5~1500 mg/kg时,回收率为84.9%~105%,相对标准偏差(RSD, n=6)为3.2%~6.1%。应用本方法分析了15个样品,阳性样品检出率为53.3%。该法前处理简单,回收率高,精密度好,适用于洗涤用品中4种荧光增白剂的测定。

关 键 词:超高效液相色谱-二极管阵列检测器  固相萃取  洗涤用品  荧光增白剂  
收稿时间:2012-09-28

Determination of four fluorescent whitening agents in laundry detergents by solid phase extraction combined with ultra-high performance liquid chromatography
XIAN Yanping,GUO Xindong,LUO Haiying,WU Yuluan, CHEN Yiguang,LUO Donghui,WU Wenhai.Determination of four fluorescent whitening agents in laundry detergents by solid phase extraction combined with ultra-high performance liquid chromatography[J].Chinese Journal of Chromatography,2013,31(2):162-169.
Authors:XIAN Yanping  GUO Xindong  LUO Haiying  WU Yuluan  CHEN Yiguang  LUO Donghui  WU Wenhai
Institution:Guangzhou Quality Supervision and Testing Institute, National Centre for Quality Supervision and Testing of Cosmetics (Guangzhou), Guangzhou 510110, China
Abstract:A new method was established to determine three stilbene-type disulfonate and one distyrylbiphenyl-type fluorescent whitening agents (FWA351, FWA85, FWA28 and FWA71) in laundry detergents by solid phase extraction (SPE) and ultra-high performance liquid chromatography with a diode array detector (UPLC-DAD). The fluorescent whitening agents were extracted from laundry detergents with 2% formic acid aqueous solution and methanol, and purified by WAX SPE column, and analyzed by UPLC-DAD on a Phenomenex Synergi Max-RP column (150 mm×2.0 mm), employing acetonitrile-10 mmol/L ammonium acetate as the mobile phase in a gradient elution mode. The fluorescent whitening agents were qualitatively determined by retention time, and confirmed by the ultraviolet spectrum. The results indicated that the target analytes were in the range of 0.05-180 mg/L with the correlation coefficients (r) greater than 0.9993, and the method limits of quantification (MLOQ) of target analytes were ranged from 1.5 mg/kg to 15 mg/kg (S/N=10). The feasibility of this method was demonstrated by the determination of FWAs in samples with spiked recoveries. The recoveries were in the range between 84.9% and 105%, and the precision (relative standard deviation, RSD) ranged from 3.2% to 6.1% (n=6). Among the 15 samples analyzed, the rate of positive samples was 53.3%, over 1000 mg/kg of FWA351 and FWA71 were detected. The method is simple, precise and has high recoveries for the determination of fluorescent whitening agents in laundry detergent samples.
Keywords:solid-phase extraction (SPE)  ultra-high performance liquid chromatography-diode array detector (UPLC-DAD)  fluorescent whitening agents (FWAs)  laundry detergents
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号