塞曼效应实验中F.P标准具的快速调试
引用本文:刘忠民,周琳.塞曼效应实验中F.P标准具的快速调试[J].大学物理实验,2010,23(1):19-21.
作者姓名:刘忠民  周琳
作者单位:1. 江西师范大学,江西,南昌330022
2. 江西省信息科技学校,江西,南昌330029
摘    要:F-P标准具是塞曼效应实验仪器的核心元件,正确保养和调试非常重要。分析了F-P标准具的结构和成像原理,介绍了F-P标准具的快速调度方法。从而提高了仪器的使用寿命和师生动手操作等能力。

关 键 词:F-P标准具  结构  快速调试

Quick Adjustment of F-P Etalon in Zeema-effect Experment
LIU Zhong-min,ZHOU Lin.Quick Adjustment of F-P Etalon in Zeema-effect Experment[J].Physical Experiment of College,2010,23(1):19-21.
Authors:LIU Zhong-min  ZHOU Lin
Institution:LIU Zhong-min1,ZHOU Lin2 (1.Jiangxi Normal University,Nanchang 330022,2.Jiangxi Information Technology School,Nanchang 330029)
Abstract:F-P etalon is the core component in Zeeman effect,it is very important to proper maintenance and adjustment.Analysised the structure and imaging principle about F-P etalon,introduced quick adjustment method of F-P etalon.Improve the life of equipment and operation capacity of teachers and students.
Keywords:F-P etalon  structure  imaging principle  quick adjustment  