首页 | 本学科首页   官方微博 | 高级检索  
     


Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound
Authors:Richard P. Erickson  Waleed M. Maswadeh  Philip A. Smith
Affiliation:a Uniformed Services University of the Health Sciences, Preventive Medicine and Biometrics Department, 4301 Jones Bridge Road, Bethesda, MD 20814-4799, USA
b Geo-Centers, Inc., Aberdeen Proving Ground, MD 21010-5424, USA
c U.S. Army Edgewood Chemical Biological Center, Building E3160, Aberdeen Proving Ground, MD 21010-5424, USA
d Naval Medical Center San Diego, Industrial Hygiene Department, 34800 Bob Wilson Drive, San Diego, CA 92134-5000, USA
Abstract:Ion mobility spectrometry (IMS) is a proven technology for detection of vapor phase chemical warfare agents. The technology is suitable for field portable instrumentation due to its small size, high sensitivity, speed of analysis, and low power consumption. However, it suffers from a limited dynamic range and potential difficulties in identifying compounds in complex matrices. The use of gas chromatography (GC) coupled to IMS can overcome the difficulty of chemical identification in mixtures by separating the sample into individual components before detection. Using this approach, IMS technology has previously been adapted to detect biological aerosols using an open tube pyrolyzer and a short GC column (Py-GC-IMS). The open sample introduction tube of a Py-GC-IMS instrument would be a convenient configuration to accept aerosol particulates, and while viewed as needed for aerosol trapping, is not optimal for liquid chemical analyses. To examine the usefulness of an existing Py-GC-IMS system for analysis of chemicals in water, an existing open-port sample interface was replaced with a septum-equipped closed tube injector to contain analyte vapors resulting from liquid injection. Tributylphosphate (TBP) was used as a surrogate chemical warfare agent, and aqueous injections into both closed and open tube assemblies were performed. Sample introduction into the closed tube inlet was also accomplished using solid phase microextraction (SPME) preconcentration. The limit of detection for TBP using an open tube, closed tube, and closed tube configuration with SPME sample introduction was 0.980, 0.196, and 0.0098 mg/L, respectively.
Keywords:Field analysis   Gas chromatography   Ion mobility spectrometry   Solid phase microextraction   Resistive heating   Chemical warfare agent
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号