Newly developed highly sensitive LiF:Mg,Cu,Si TL discs with good stability to heat treatment
Authors:K. Tang  H. Cui  H. Zhu  Z. Liu  H. Fan
Affiliation:Solid Dosimetric Detector and Method Laboratory, P.O. Box 1044 Ext. 204, Beijing 102205, PR China
Abstract:The preparation method and some dosimetric properties of the new LiF:Mg,Cu,Si discs are presented. The effect of heat treatments on LiF:Mg,Cu,Si was investigated. The shape of the glow curve for LiF:Mg,Cu,Si is similar to that for standard LiF:Mg,Cu,P (GR-200A), and shows minimal differences when annealed in the range from 260 °C to 290 °C for 10 min. The TL sensitivity for LiF:Mg,Cu,Si is much lower than that for GR-200A, but is 35 times larger than that for TLD-100 and is slightly higher than that for HMCP. The height of the high-temperature peaks for LiF:Mg,Cu,Si is not only lower than that for GR-200A, but also lower than that for HMCP. The glow curve shape of LiF:Mg,Cu,Si annealed at 260 °C for different times shows minimal differences and TL response remains stable. These results indicate that the new LiF:Mg,Cu,Si disc has a good stability to thermal treatments and a lower residual TL signal.
Keywords:
本文献已被 ScienceDirect 等数据库收录!