首页 | 本学科首页   官方微博 | 高级检索  
     

LED蓝光泄露安全性研究
引用本文:申崇渝,徐征,赵谡玲,黄清雨. LED蓝光泄露安全性研究[J]. 光谱学与光谱分析, 2014, 34(2): 316-321. DOI: 10.3964/j.issn.1000-0593(2014)02-0316-06
作者姓名:申崇渝  徐征  赵谡玲  黄清雨
作者单位:北京交通大学发光与光信息技术教育部重点实验室, 北京交通大学光电子技术研究所,北京 100044
基金项目:国家重点基础研究发展计划(973计划)项目(2010CB327704), 国家自然科学基金项目(51272022), 教育部新世纪优秀人才支持计划项目(NCET-10-0220), 教育部博士点基金项目(20120009130005), 中央高校基本科研业务费专项资金项目(2012JBZ001), 国家高技术研究发展计划(863计划)项目(2013AA032205), 教育部博士点基金项目(20130009130001)资助
摘    要:研究了LED照明器件的蓝光特性。针对我国的LED照明现状,通过测试LED照明器件的光谱成分,根据现行国内外标准GB/T 20145—2006/CIE S009/E:2002和IEC62471:2006,以及CTL-0744_2009-laser决议,分析了LED光生物安全性,给LED照明灯具制造和相关安全性标准、法律制定提供参考。LED中蓝光的辐亮度值低于100 W·m-2·Sr-1时对人眼属于无危害类型,正常使用情况下不会对人眼造成伤害,但是应该注意对特殊人群(小孩)的保护,避免长时间直视光源。灯具富蓝化也会影响人的作息规律,因此色温4 000 K以下,显色指数80的LED灯具适合在室内使用,同时还要根据不同的使用距离选择不同的参数的灯具。

关 键 词:LED  蓝光泄露  光生物安全  光谱辐亮度  色温   
收稿时间:2013-05-13

Study on the Safety of Blue Light Leak of LED
SHEN Chong-yu,XU Zheng,ZHAO Su-ling,HUANG Qing-yu. Study on the Safety of Blue Light Leak of LED[J]. Spectroscopy and Spectral Analysis, 2014, 34(2): 316-321. DOI: 10.3964/j.issn.1000-0593(2014)02-0316-06
Authors:SHEN Chong-yu  XU Zheng  ZHAO Su-ling  HUANG Qing-yu
Affiliation:Key Laboratory of Luminescence and Optical Information of Ministry of Education, Beijing Jiaotong University, Beijing 100044,China
Abstract:In this paper, the blue light properties of LED illumination devices have been investigated. Against the status quo of China’s LED lighting, we measured the spectrum component of LED lamps and analyzed the photobiological safety under the current domestic and international standards GB/T 20145-2006/CIE S009/E: 2002 and IEC62471: 2006 standards as well as CTL-0744_2009-laser resolution, which provides the reference to the manufacture of LED lighting lamps as well as related safety standards and laws. If the radiance intensity of blue light in LED is lower than 100 W·m-2·Sr-1, there is no harm to human eyes. LEDs will not cause harm to human eyes under normal use, but we should pay attention to the protection of special populations (children), and make sure that they avoid looking at a light source for a long time. The research has found that the blue-rich lamps can affect the human rule of work and rest, and therefore, the LED lamps with color temperature below 4 000 K and color rendering index of 80 are suitable for indoor use. At the same time, the lamps with different parameters should be selected according to the different distances.
Keywords:LED  Blue light leak  Photobiological safety  Spectral irradiance  Colour temperature
本文献已被 CNKI 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号