Quantitation of mercapturic acids from acrylamide and glycidamide in human urine using a column switching tool with two trap columns and electrospray tandem mass spectrometry
Authors:Kellert Marco  Scholz Karoline  Wagner Silvia  Dekant Wolfgang  Völkel Wolfgang
Affiliation:Department of Toxicology, University of Würzburg, Versbacher Strasse 9, 97078 Würzburg, Germany.
Abstract:A sensitive and specific electrospray tandem mass spectrometry method using a column switching unit with two trap columns was established to quantify the mercapturates (MAs) of acrylamide (AA) and glycidamide (GA) in human urine. A specially endcapped material was applied for trapping the hydrophilic MAs and a pre-trap column was used to remove lipophilic compounds from the directly injected urine to protect the trap column. The limits of quantitation for AA-MA and GA-MA in urine were 0.5 microg/L and 1 microg/L, respectively. Urine was spiked with deuterated internal standards and injected directly into LC-MS/MS. Urine of smokers (n=13) revealed the highest concentrations of AA-MA and GA-MA in the range of 61-706 microg/L and 5-54 microg/L, respectively. Lower levels for AA-MA (14-102 microg/L) and GA-MA (1-11 microg/L) were detected in non-smokers (n=13).