摘    要:研究了电感耦合等离子体质谱(ICP-MS)同时测定土样中痕量铂、铑、钯的分析方法。比较几种尘土样品的消解处理方法,采用王水加热回流来消解样品。优化了样品测量条件,并研究了干扰情况和消除干扰的方法。所建立的方法的精密度、线性关系良好,在优化的实验条件下Pt,Pd,Rh的检出限分别为0.48,4.22和0.42 ng·g-1,样品的加标回收率分别为Pt 87.6%~88%,Pd 85.2%~87.8%和Rh 93%~95%。将建立的方法应用于环境尘土样品的测定,回收率在85%以上,结果令人满意。

关 键 词:铂族元素  ICP-MS  环境尘土样品  王水消解
文章编号:1000-0593(2006)04-0741-06
收稿时间:2005-01-30
修稿时间:2005-05-08

Simultaneous Determination of Trace Platinum, Palladium and Rhodium in Environmental Dust Samples by ICP-MS after Open-Digestion
SHI Yan-zhi,HE Run-juan,WANG Juan,ZHU Ruo-hua. Simultaneous Determination of Trace Platinum, Palladium and Rhodium in Environmental Dust Samples by ICP-MS after Open-Digestion[J]. Spectroscopy and Spectral Analysis, 2006, 26(4): 741-746
Authors:SHI Yan-zhi  HE Run-juan  WANG Juan  ZHU Ruo-hua
Affiliation:1. Center of Analysis and Testing, Capital Normal University, Beijing 100037, China2. Department of Chemistry, Capital Normal University, Beijing 100037, China
Abstract:A sensitive method for simultaneous determination of Pt, Pd and Rh in dust samples by ICP-MS after open-digestion was developed. The digestion method for the samples and conditions for measurement for ICP-MS were studied in detail. Aquaregia was proved to be a better solvent for the digestion of dust samples. Under the optimum conditions, the limits of detection of Pt, Pd and Rh were 0.48, 4.22 and 0.42 ng x g(-1), respectively. The proposed method was applied to the real sample analysis, and good recoveries were obtained. The recoveries of Pt, Pd and Rh were found to be between 87.6%-88%, 85.2%-87.8%, and 93%-95%, respectively.
Keywords:PGE   ICP-MS   Environmental dust samples   Digestion with Aqua-regia