Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk
Authors:Patricia Cava-Montesinos  Agustin Pastor  Miguel de la Guardia
Institution:Department of Analytical Chemistry, University of Valencia, Research Building, 50 Dr. Moliner Street, 46100 Burjassot, Valencia, Spain
Abstract:A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.
Keywords:Milk analysis  Selenium determination  Tellurium determination  Hydride generation atomic fluorescence  Microwave-assisted digestion