首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of chromium, cadmium and lead in food-packaging materials by axial inductively coupled plasma time-of-flight mass spectrometry
Authors:El?bieta Skrzydlewska  Maria Balcerzak  Frank Vanhaecke
Affiliation:a Department of Analytical Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland
b Polish Packaging Research and Development Centre, Konstancińska 11, 02-942 Warsaw, Poland
c Laboratory of Analytical Chemistry, Institute for Nuclear Sciences, Ghent University, Proeftuinstraat 86, B-9000 Ghent, Belgium
Abstract:Inductively coupled plasma mass spectrometry (ICP-MS) with a time-of-flight (TOF) analyser was used for the determination of chromium, cadmium and lead in six food-packaging materials (paper and paper board). The samples (0.20-0.25 g) were digested in concentrated nitric acid in a high pressure microwave oven at 180 °C within 15 min. Two different plasma conditions were applied: cool plasma conditions (0.76 kW; 0.85, 0.89 and 15.5 l min−1 nebuliser, auxiliary and plasma gas flow rate, respectively) for the determination of chromium and normal plasma conditions (1.21 kW; 0.66, 0.68 and 13.6 l min−1 nebuliser, auxiliary and plasma gas flow rate, respectively) for the determination of cadmium and lead. External calibration was used in combination with rhodium (40 ng g−1) as an internal standard. The detection limits (DL = 3S.D./sensitivity) under the conditions used corresponded to 0.01 ng g−1 (View the MathML source), 0.06 ng g−1 (View the MathML source), 0.07 ng g−1 (View the MathML source), 0.03 ng g−1 (View the MathML source) and 0.02 ng g−1 (View the MathML source and View the MathML source). The precision (R.S.D.) for six replicate determinations (10 s integration time) of 1 and 10 ng g−1 of each analyte varied from 0.72% (View the MathML source) to 4.43% (View the MathML source). The contents of chromium, cadmium and lead in the examined materials were evaluated using the signals of View the MathML source, View the MathML source and View the MathML source. They were in the range: 0.25-0.50 μg g−1 for Cr, not detected (nd) to 0.12 μg g−1 for Cd and 0.28-0.35 μg g−1 for Pb in paper and 0.50-0.64 μg g−1 for Cr, nd to 0.09 μg g−1 for Cd and 0.67-0.99 μg g−1 for Pb in paper board.
Keywords:Chromium   Cadmium   Lead   Food-packaging materials   Inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS)
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号