Non-destructive determination of low-level210Pb and226Ra with an ordinary high-purity Ge-detector |
| |
Authors: | Y Ishikawa H Murakami T Sekine T Saito K Yoshihara |
| |
Institution: | (1) Environmental Radioactivity Research Institute of Miyagi, Ise, 986-22 Onagawa-cho, (Japan);(2) Department of Chemistry, Faculty of Science, Tohoku University, Aoba-ku, 980 Sendai, (Japan) |
| |
Abstract: | A convenient non-destructive method for the determination of low level210Pb and226Ra with an ordinary high-purity Ge-detector is presented. The ordinary Ge-detectors used in this work were available to measure 46.5 keV -rays of210Pb. These detectors were also useful for the non-destructive analysis of low-level226Ra in lime-stone and calcium chemicals when a stream of nitrogen gas was maintained around the detectors. By this method, measurements could be carried out not only for210Pb and226Ra but also for other -emitting radionuclides simultaneously, using the same detector. The detection limits of about 1 Bq per sample for210Pb and about 0.05 Bq per sample for226Ra, respectively, were estimated, when the samples were counted for 1–2 days. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|