Continuous determination of hydrogen fluoride in air with the fluoride-selective electrode
Authors:Kunio Nagashima  Yasutaka Fujihira  Shigetaka Suzuki
Affiliation:Department of Industrial Chemistry, Faculty of Technology, Tokyo Metropolitan University, Setagaya-ku, Tokyo 158 Japan
Abstract:Hydrogen fluoride in a standard or sample gas stream at 200 ml min?1 permeates through a teflon membrane (0.8 μm pore size, 0.08 mm thick) into an absorption solution (citrate/acetate buffer at pH 5.4) flowing at 30 ml min?1. The fluoride produced is measured with the fluoride-selective electrode. The response time is about 12 min. The absorption efficiency of hydrogen fluoride is about 70% between 6.5 and 0.25 ppm by volume (5.2 and 0.2 mg m?3). In this range, the Nernst equation is valid with a relative standard deviation of less than 1.8%. The lower determination limit for hydrogen fluoride is 0.1 ppm (0.08 mg m?3).