首页 | 本学科首页   官方微博 | 高级检索  
     


Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor
Authors:Goossens Jozefien  Martinez Loïc  Glorieux Christ  Wilkie-Chancellier Nicolas  Ehssein Chighali Ould  Serfaty Stéphane
Affiliation:Laboratorium voor Akoestiek en Thermische Fysica, Departement Natuurkunde en sterrenkunde, Celestijnenlaan 200D, 3001 Heverlee, Belgium. Jozefien.goossens@fys.kuleuven.be
Abstract:Laser ultrasonic detection is a versatile and highly sensitive tool for the observation of surface waves. In the following study, laser ultrasonic detection is used for the experimental study of spurious normal vibration modes of a disk quartz sensor excited by a voltage pulse. The AT cut crystal (cut of the crystal relative to the the main crystallographic axis is 35.25 degrees) is optimal for generating mainly thickness-shear vibrations (central frequency 6 MHz) on the quartz surface. However, resulting from shear-to-longitudinal and shear-to-surface mode conversion, and from the weak coupling with the other crystallographic axes, other modes (thickness-compressional and bending modes) are always present in the plate response. Since the laser vibrometer is sensitive to normal displacements, the laser investigation shows waves that can be considered as unwanted for the AT quartz used as a shear sensor. The scanned three dimensional (3D) amplitude-space-time signals are carefully analysed using their representation in three dual Fourier domains (space-time, wave number-frequency). Results on the transient analysis of the waves, the normal bending modes and the dispersion curves are shown.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏