首页 | 本学科首页   官方微博 | 高级检索  
     检索      


2,5-Dihydroxyacetophenone oxime as an analytical reagent for the amperometric determination of copper,palladium, and nickel
Authors:B D Gupta  W U Malik
Institution:(1) Chemical Laboratories, University of Roorkee, Roorkee, India
Abstract:Summary Copper, palladium and nickel can be titrated amperometrically with 2,5-dihydroxyacetophenone oxime at –0.15, –0.4 and, –1.2 V vs. S. C. E. respectively, the optimum pH values being 4.6, 4.0, and 9.0. Alkali and alkaline earth metals, Al, Bi, Cd, Co, Cr. Fe(II), Hg, Mn, Ni, Pb, Th, Zn, UO, W, and Zr do not interfere with the estimation of copper and palladium. The interferences due to the presence of silver and iron(III) can be eliminated by adding excess of KCl and KF respectively. Most heavy metals interfere with the estimation of nickel and should be eliminated before titration.
Zusammenfassung Kupfer, Palladium und Nickel können mit 2,5-Dihydroxyaeetophenonoxim bei –0,15, –0,4 bzw. –1,2 V gegen eine gesättigte Kalomelelektrode amperometrisch titriert werden, wobei man das pH am besten auf 4,6, 4,0 bzw. 9,0 hält. Alkalimetalle, Erdalkalien, Al, Bi, Cd, Co, Cr, Fe(II), Hg, Mn, Ni, Pb, Th, Zn, UO2, W und Zr stören die Bestimmung des Kupfers und des Palladiums. Silber und Eisen können mit Kaliumchlorid gefällt bzw. mit Kaliumfluorid maskiert werden. Die meisten Schwermetalle stören die Nickelbestimmung und müssen daher vor der Titration entfernt werden.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号