Study of the RPC-Gd as thermal neutron detector
Authors:QIAN Sen  WANG Yi-Fang  ZHANG Jia-Wen  LI Jin  CHEN yuan-Bo  CHEN Jin  WANG Zhi-Gang  MA Lie-Hua
Abstract:The BESⅢ RPC with Gd coating as thermal neutron detector was designed and constructed. Three prototypes were built with different techniques of producing the gadolinium converter. The performance of the cosmic ray test, the signal and the radiation spectrum were discussed in this paper. Lastly, the efficiency of one prototype with the best performance for detecting the thermal neutron was tested as 8.7%.
Keywords:RPC  Gd  thermal neutron