Reliable determination of 237Np in environmental solid samples using 242Pu as a potential tracer
Authors:Qiao Jixin  Hou Xiaolin  Roos Per  Miró Manuel
Institution:a Radiation Research Division, Risø National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde, Denmark
b Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, E-07122 Palma de Mallorca, Illes Balears, Spain
Abstract:This paper reports an analytical method for rapid determination of neptunium (237Np) in environmental solid samples exploiting automated sequential injection (SI)-based anion exchange separation. Pivotal issues on analytical method performance were investigated including sorption behavior of 237Np onto various AG 1-type anion exchangers; suitability of 242Pu as a tracer for 237Np determination in environmental solid samples; and long-term chemical stability of tetravalent Np. Experimental results revealed that the degree of resin cross-linking has a significant influence on the separation efficiency in terms of chemical yields of 237Np and removal of interfering nuclides. Although ca. 30% of sorbed Np onto AG 1-×4 was stripped out during HCl rinsing step for the removal of Th, chemical yield ratios of 237Np to 242Pu were proven steady with an average value of 0.67 ± 0.04 (n = 15) under selected experimental conditions. Disulfite-8 M HNO3 was selected as a redox pair for valence adjustment to Np(IV) and the tetravalent Np in the sample solution was demonstrated to be stabilized for up to 5 days under 3 °C. The analytical results for reference materials showed a good agreement with the expected values, thereby demonstrating the usefulness of 242Pu as a non-isotopic tracer for 237Np chemical yield monitoring. The on-column separation procedure fosters rapid analysis as required in emergency situations since each individual sample can be handled within 2.5 h, and leads to a significant decrease in labor intensity compared to conventional batch-wise protocols.
Keywords:237Np  242Pu  Non-isotopic tracer  Rapid analysis  Automatization  Environmental samples  Anion exchange chromatography  Sequential injection  ICP-MS
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号