首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高强方钢管轻骨料混凝土桁架加劲搭接K形节点承载力研究
引用本文:王政通 宓竹锟 潘,鹏 王万祯 吴晓聪.高强方钢管轻骨料混凝土桁架加劲搭接K形节点承载力研究[J].宁波大学学报(理工版),2022,0(5):64-71.
作者姓名:王政通 宓竹锟 潘  鹏 王万祯 吴晓聪
作者单位:1.宁波大学 土木与环境工程学院, 浙江 宁波 315211; 2.洛阳理工学院 土木工程学院, 河南 洛阳 471023
摘    要:对高强方钢管轻骨料混凝土桁架加劲搭接K形节点和基本型节点进行主管轴压静力加载试验, 考察了支管搭接率和加劲板构造对节点受力性能的影响. 试验结果表明: 节点的破坏模式为支管根部侧面搭接焊缝开裂; 支管搭接率过大或过小均会降低搭接K形节点承载力; 加劲节点的屈服荷载和极限荷载较基本型节点分别提高6.5%和12.0%. 同时, 对高强方钢管轻骨料混凝土桁架加劲搭接K形节点进行了数值模拟、热点应力场演化分析和破坏机理探究, 推导了极限承载力计算式. 通过与节点试验结果对比, 验证了该计算式的精度.

关 键 词:高强方钢管  轻骨料混凝土  加劲搭接K形节点  加载试验  数值模拟  承载力计算

Bearing capacity of lightweight aggregate concrete-filled high strength square steel tube truss with stiffened lapped K-joint
WANG Zhengtong,MI Zhukun,PAN Peng,WANG Wanzhen,WU Xiaocong.Bearing capacity of lightweight aggregate concrete-filled high strength square steel tube truss with stiffened lapped K-joint[J].Journal of Ningbo University(Natural Science and Engineering Edition),2022,0(5):64-71.
Authors:WANG Zhengtong  MI Zhukun  PAN Peng  WANG Wanzhen  WU Xiaocong
Institution:1.School of Civil and Environmental Engineering, Ningbo University, Ningbo 315211, China; 2.School of Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
Abstract:In order to study the effect of braces lap ratio and stiffening plates on the performance of lightweight aggregate concrete-filled high strength square steel tube truss with lapped K-joint, static loading tests under axial compression were performed on stiffened lapped K-joints and traditional lapped K-joint. Tests results show that crack of lapped weld between braces is the typical failure mode of the lapped K-joint. Too large or too small overlap ratio can reduce the bearing capacity of the lapped K-joint. The yield load and ultimate bearing capacity of the stiffened lapped K-joint increase by 6.5% and 12.0% respectively compared with those of the traditional lapped K-joint. The numerical simulation, hot spot stress evolution and failure mechanism analysis of the lapped K-joints were also carried out. The formula for calculating the ultimate bearing capacity of the lapped K-joint was proposed. Compared with the test results, the accuracy of the proposed formula for calculating the ultimate bearing capacity of the lapped K-joint was verified.
Keywords:stiffened lapped K-joint  high strength square steel tube  lightweight aggregate concrete  test  numerical simulation  formula for calculating the ultimate bearing capacity