首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Automated analysis of immediate reliability of T2 and T2* relaxation times of hip joint cartilage from 3 T MR examinations
Institution:1. Department of Pathology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030;2. Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030;3. Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030;4. Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030;5. Gastrointestinal Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030
Abstract:BackgroundMagnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA).PurposeTo evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling.Study typeTechnical validation.Subjects17 asymptomatic volunteers (M: F 7:10, aged 22–47 years, mass 50–90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence.Field strength/sequenceA 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18–90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82–19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel).AssessmentAutomated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability.Statistical testsCoefficient of variation (CV) and intraclass correlations (ICC2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint.ResultsComparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC2, 1′s of 0.871 (0.984) and median mean differences of ?1.139ms (+0.195ms).ConclusionThe T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号