Ultrasonic anechoic chamber qualification: accounting for atmospheric absorption and transducer directivity |
| |
Authors: | Jenny Trevor Anderson Brian E |
| |
Institution: | Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602, USA. tdwheats@hotmail.com |
| |
Abstract: | Qualifying an anechoic chamber for frequencies that extend into the ultrasonic range is necessary for research work involving airborne ultrasonic sound. The ANSI S12.55/ISO 3745 standard which covers anechoic chamber qualification does not extend into the ultrasonic frequency range, nor have issues pertinent to this frequency range been fully discussed in the literature. An increasing number of technologies employ ultrasound; hence the need for an ultrasonic anechoic chamber. This paper will specifically discuss the need to account for atmospheric absorption and issues pertaining to source transducer directivity by presenting some results for qualification of a chamber at Brigham Young University. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|