首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Wavelength modulation spectroscopy at 1530.32 nm for measurements of acetylene based on Fabry–Perot tunable filter
引用本文:李运龙,杨兵初,许雪梅.Wavelength modulation spectroscopy at 1530.32 nm for measurements of acetylene based on Fabry–Perot tunable filter[J].中国物理 B,2016,25(2):24208-024208.
作者姓名:李运龙  杨兵初  许雪梅
作者单位:School of Physics and Electronics, Central South University, Changsha 410083, China
基金项目:Project supported by the National Natural Science Foundation of China (Grant Nos. 61172047 and 61071025).
摘    要:Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications.

收稿时间:2015-05-24

Wavelength modulation spectroscopy at 1530.32 nm for measurements of acetylene based on Fabry-Perot tunable filter
Institution:School of Physics and Electronics, Central South University, Changsha 410083, China
Abstract:Sensitive detection of acetylene (C2H2) is performed by absorption spectroscopy and wavelength modulation spectroscopy (WMS) based on Fiber Fabry-Perot tunable filter (FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating (FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv-400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C2H2 detection can be applied in practical applications.
Keywords:absorption spectroscopy  Fabry-Perot tunable filter  wavelength modulation  acetylene detection  