首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Experimental studies on the hydrogen isotope recovery using low-pressure palladium membrane diffuser
Authors:Yan Shi  Yong-Jun WeiYong-Jun Su
Institution:China Academy of Engineering Physics, P.O. Box 919-71, Mianyang 621900, Sichuan, PR China
Abstract:In this paper, we introduce a set of low-pressure palladium membrane diffuser designed to recover hydrogen isotopes from inert mixture gases. Several gaseous mixtures (D2/Ar and D2/He) with different deuterium concentration have been used for cleanup test of the low-pressure palladium membrane diffuser at 723 K. Effect of the composition of feed gas on the pressure of permeate side has been observed by gas chromatography (GC) and pressure sensor. With the feed flow rate of the mixture gases increasing, the D2 permeate pressure is increasing as well. Decontamination factor (DF) of more than 1000 and recovery efficiency greater than 99.9% have been obtained by controlling the feed gas flow rate. The same palladium membrane diffuser was used to process helium-3 gas with more than 10% hydrogen isotope and about 0.3% tritium gas. The pure helium-3 (above 99.4%) with low content of hydrogen isotopes (about 0.084%) has been obtained. Recovery efficiency of all hydrogen isotopes is 99.5% above.
Keywords:Low-pressure palladium membrane diffuser  Decontamination factor  Hydrogen isotope recovery  Inert gas  Tritium
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏