首页 | 本学科首页   官方微博 | 高级检索  
     


Characterization of pneumatic fast transfer system irradiation position of KAMINI reactor for k 0-based NAA
Authors:J. S. Brahmaji Rao  E. Senthilvadivu  N. P. Seshadreesan  R. Acharya  C. R. Venkatasubramani  A. V. R. Reddy
Affiliation:1. Fuel Chemistry Division, Chemistry Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, 603 102, India
2. Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400 085, India
3. Analytical Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400 085, India
Abstract:The pneumatic fast transfer system position at KAMINI reactor, Indira Gandhi Centre for Atomic Research, India was characterized by determining the epithermal neutron flux shape factor (α) and the sub-cadmium to epithermal neutron flux ratio (f) for k 0-based Neutron Activation Analysis (k 0-NAA). For determination of α value, bare, Cd-ratio and Cd-cover methods were employed using dual and multi monitors namely Au, Zr and Zn. For calculation of f, Au and Zr monitors were used in the case of bare method and Au monitor was used for cadmium ratio and cadmium cover methods. The determined α-value of PFTS indicated a hard epithermal neutron spectrum and the f value indicated about 96 % thermal neutron component. For validation of k 0-NAA method, reference materials namely NIST SRM 1646a (Estuarine Sediment) and BCS Nb-stabilized Stainless Steel (BCS/SS No.261/1) were analyzed. The percentage errors of the determined concentration values of elements were within ±5 % with respect to the certified values and the Z-score values at 95 % confidence level were within ±2 in most of the cases.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号