首页 | 本学科首页   官方微博 | 高级检索  
     


Large sample neutron activation analysis of dross for gold and silver
Authors:K. K. Swain  Nicy Ajith  R. Acharya  R. Verma  A. V. R. Reddy
Affiliation:1. Analytical Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400 085, India
2. Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400 085, India
Abstract:Large sample neutron activation analysis of dross from India Government Mint, Mumbai was carried out for quantification of gold (Au) and silver (Ag) using graphite reflector position of Advanced Heavy Water Reactor critical facility at Bhabha Atomic Research Centre, Mumbai. The k 0-based internal monostandard NAA was used to calculate concentration ratios of Au and Ag with respect to sodium (Na), which was used as an internal monostandard. The concentration ratio values of Au to Na of varying mass of dross showed that mass ≥2 g was the representative sample size for analysis. Concentrations of gold and silver were found to be in the range of 200–400 and 1200–1700 mg kg?1, respectively in three different samples.
Keywords:
本文献已被 SpringerLink 等数据库收录!