MIRE-IL methodology applied to measuring the noise attenuation of earmuff hearing protectors
Authors:Danilo de Almeida-Agurto  Samir NY Gerges  Jorge P Arenas
Institution:aLaboratory of Acoustics and Vibration, Dept. of Mechanical Engineering, Univ. Federal de Santa Catarina, CP476 Florianopolis, Brazil;bInstitute of Acoustics, Univ. Austral de Chile, PO Box 567, Valdivia, Chile
Abstract:This article describes an objective methodology for measuring the noise attenuation of earmuff hearing protectors using as a reference the method known as microphone-in-real-ear (MIRE). The methodology implements the insertion loss (IL) paradigm, in which IL is measured using miniature microphones, specially designed to comply with ANSI and ISO standards for the MIRE technique. The results for four different hearing protectors are compared with the subjective method known as real-ear-attenuation-at-threshold (REAT). Correction factors are included in the methodology to account for external effects such as physiological noise and bone conduction. The objective method predicted well the real protection of the earmuffs and the proposed methodology showed lower standard deviation values than the REAT method.
Keywords:Hearing protectors  Noise attenuation  Insertion loss  MIRE  REAT
本文献已被 ScienceDirect 等数据库收录!