首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Intensitäten myonischer Röntgenlinien in SF6 und H2 plus SF6
Authors:Dr H -J Pfeiffer  H Daniel
Institution:1. Physik-Department der Technischen Universit?t München, Deutschland
2. Schweizerisches Institut für Nuklearforschung-SIN, CH-5234, Villigen, Schweiz
Abstract:Muonic X-ray spectra from S and F in SF6 and H2+SF6 have been measured with a high-pressure gas target. Strong differences between the observed intensities of corresponding lines were found for the two cases. The results are compared with cascade calculations. The per-atom ratio between Coulomb capture in F and S was determined to be 0.96±0.09 and 1.04±0.24 for SF6 and H2+SF6, respectively.