Optimization of contrast dosage for gadolinium-enhanced 3D MRA of the pulmonary and renal arteries
Institution:2. Department of Health Technology and Informatics, Hong Kong Polytechnic University, Hong Kong, China;3. Research Institute for Smart Ageing, Hong Kong Polytechnic University, Hong Kong, China;4. Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
Abstract:To determine the minimal contrast dosage required for diagnostic contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) image quality of the pulmonary (PAs) or renal arteries (RAs). In 12 volunteers (10 females, 2 males; mean age 24 years) imaging was performed with 4 different dosages: 0.05, 0.1, 0.2 and 0.3 mmol/kg of body weight (BW) 0.5 M gadolinium (Gd) contrast agent. The PAs and RAs were evaluated separately each in groups of six volunteers. Qualitative and quantitative signal-to-noise ratio (SNR) image analysis was performed. For the PAs, the increases in signal-to-noise ratio were paralleled by increases in image quality ratings. For the PAs, with the use of 0.05 mmol/kg, only 50.3% of all segments were rated diagnostic, whereas with higher dosages the percentage rose to 89.2% for 0.1 mmol/kg, 98.2% for 0.2 mmol/kg. and 99.1% for 0.3 mmol/kg. For the RAs, 0.3 mmol/kg provided no significant increase in singal-to-noise ratio compared to 0.2 mmol/kg (p = 0.4). Only by a dosage of 0.2 and 0.3 mmol/kg, all evaluated segments were diagnostic evaluable. A dose of 0.2 mmol/kg is required for proper assessment of the RAs or PAs.