首页 | 本学科首页   官方微博 | 高级检索  
     


Electro-hydrodynamic micro-fluidic mixer
Authors:El Moctar Ahmed Ould  Aubry Nadine  Batton John
Affiliation:Department of Mechanical Engineering and New Jersey Center for Micro-Flow Control, New Jersey Institute of Technology, Newark, NJ 07102, USA.
Abstract:Fluid mixing in microchannels is needed for many applications ranging from bio-arrays to micro-reactors, but is typically difficult to achieve. A simple geometry micro-mixer is proposed based on the electro-hydrodynamic (EHD) force present when the fluids to be mixed have different electrical properties and are subjected to an electric field. The electrodes are arranged so that the electric field is perpendicular to the interface between the two fluids, creating a transversal secondary flow. The technique is demonstrated experimentally using the flow of two liquids with identical viscosity and density, but different electrical properties. The volume flow rate and average velocity are 0.26 microl s(-1) and 4.2 mm s(-1), respectively, corresponding to a Reynolds number Re= 0.0174. The effect of a continuous (DC) electric field and two alternating (AC)- sinusoidal and square - electric fields is explored. At the appropriate parameter values, very good mixing takes place in less than 0.1 s, over a very short distance (within a fraction of the width 250 microm of the electrodes).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号