首页 | 本学科首页   官方微博 | 高级检索  
     检索      

煤中氯含量测定结果不确定度的评定
引用本文:史英辉.煤中氯含量测定结果不确定度的评定[J].化学分析计量,2004,13(4):9-12.
作者姓名:史英辉
作者单位:沧州出入境检验检疫局,沧州,061000
摘    要:对用GB/T3558-1996《煤中氯的测定方法》中高温燃烧水解-电位滴定法测定煤中氯含量测定结果的不确定度进行了评定。通过对影响测定结果的不确定度分量的分析和量化,求得煤中氯含量测定结果的扩展不确定度为0.003%。

关 键 词:原煤    含量测定  测定不确定度
修稿时间:2004年4月7日

EVALUATION OF THE UNCERTAINTY OF THE MEASUREMENT RESULT FOR DETERMINATION OF CHLORINE CONTENT IN COAL
Shi Yinghui.EVALUATION OF THE UNCERTAINTY OF THE MEASUREMENT RESULT FOR DETERMINATION OF CHLORINE CONTENT IN COAL[J].Chemical Analysis And Meterage,2004,13(4):9-12.
Authors:Shi Yinghui
Abstract:The uncentainty of measurement was evaluated for the determination of chlorine in coal by the method of GB/T 3558-1996, the high temperature combustion hydrolysis-potentionmetric titration method. By analyzing and quantifying the uncertainty components of the measurement results, the expanded uncertainty of measurement result of chlorine is 0.003% .