Radia Industry Co., Ltd., 168 Ooyagi, Takasaki, Gunma, 370, Japan
Abstract:
Radiation sensitivities of . pumilus and spores were examined to bremsstrahlung of 5 MeV EB and Cobalt -60 γ rays in order to confirm the effects of radiation and dose rate. Biological indicators (SPORTROL, NAmSA, USA) were irradiated with the X ray in the dose rate range of 4.7–47kGy/h. D-value of spores was 1.4–1.5 kGy, and that of was 1.1–1.3 kGy. The D-values of and have very small dose rate dependences to X ray, and the D-values are similar to those of γ ray. Dose distribution by X-ray and γ irradiation was measured for cartons containing 32 unit dialyzers. The Dmax./Dmin. of the X-ray irradiation (1.2) was smaller than that of γ ray (1.3).