De Novo Correction of Mass Measurement Error in Low Resolution Tandem MS Spectra for Shotgun Proteomics
Authors:Jarrett D Egertson  Jimmy K Eng  Michael S Bereman  Edward J Hsieh  Gennifer E Merrihew  Michael J MacCoss
Institution:1. Department of Genome Sciences, University of Washington, Seattle, WA, 98195, USA
Abstract:We report an algorithm designed for the calibration of low resolution peptide mass spectra. Our algorithm is implemented in a program called FineTune, which corrects systematic mass measurement error in 1?min, with no input required besides the mass spectra themselves. The mass measurement accuracy for a set of spectra collected on an LTQ-Velos improved 20-fold from ?C0.1776?±?0.0010?m/z to 0.0078?±?0.0006?m/z after calibration (avg?±?95?% confidence interval). The precision in mass measurement was improved due to the correction of non-linear variation in mass measurement accuracy across the m/z range.