首页 | 本学科首页   官方微博 | 高级检索  
     


Scan optimization of gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries with multiple bolus injections and in vitro validation of stenosis quantification
Affiliation:1. Kimel Family Translational Imaging-Genetics Lab, Centre for Addiction and Mental Health, Toronto, ON, Canada;2. Neurosciences and Mental Health Laboratory, Hospital for Sick Children, Toronto, ON, Canada;3. Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada;4. Douglas Mental Health University Institute, Verdun, QC, Canada;5. Department of Psychiatry, McGill University, Montreal, QC, Canada;6. Department of Psychiatry, University of Toronto, Toronto, ON, Canada;7. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada;8. Rotman Research Institute, Baycrest, Toronto, ON, Canada;9. Institute of Medical Science, University of Toronto, Toronto, ON, Canada
Abstract:In this study, a T1-weighted three-dimensional (3D) spoiled gradient-echo scanning protocol was developed to image the complete arterial system of the pelvis and both legs along their entire length in patients with peripheral arterial disease. Three adjacent stations were to be acquired consecutively, with some overlap, to image the entire area of interest; per station one gadolinium (Gd) contrast bolus would be administered. In an in vitro phantom study, the scanning protocol was optimized. The optimal flip angle was found to be 50°. Also, the optimal scan delay was chosen to be equal to the arrival time of the contrast bolus, thereby minimizing artifacts. Three contrast bolus injections showed sufficient enhancement of the vessels after image subtraction. Finally, stenosis quantification by manual caliper was performed by five observers in the magnetic resonance angiography (MRA) images and correlated with the percent diameter reduction determined by quantitative angiography from corresponding X-ray images. The MRA measurements were reproducible, and intra- and interobserver variabilities were statistically non-significant (p = 0.54 and p = 0.12, respectively). Stenosis quantification performed by four observers showed a good correlation with the X-ray-derived values (rP > 0.90, p < 0.02); the results from one observer were not significantly correlated. Five patients with proven peripheral disease were investigated with this new MRA scanning protocol, using standard hardware and software. The images were of good quality, which allowed adequate clinical evaluation; the original diagnoses obtained from X-ray examinations, were confirmed with MRA. In conclusion, peripheral arterial disease can be evaluated adequately with this magnetic resonance scanning protocol.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号