引用本文:王莉,张晓红,冯娅男.电感耦合等离子体质谱法测定土壤中镉和总汞[J].化学分析计量,2017,26(3):64-66.
作者姓名:王莉  张晓红  冯娅男
作者单位:1. 烟台出入境检验检疫局,山东烟台,264200;2. 烟台莱特轻纺产品检测中心,山东烟台,264200
摘    要:建立电感耦合等离子质谱法测定土壤中镉和总汞的方法。土壤样品在电热板上用盐酸和硝酸于100℃低温消解,重量法定容,取上清液上机测定。镉和总汞含量分别在0.502~10.20 ng/g,0.212~5.010 ng/g范围内线性良好,相关系数(r2)大于0.999,土壤中镉和总汞的检出限分别为0.021,0.002μg/g,测定结果的相对标准偏差分别为1.99%,5.57%(n=6),加标回收率分别为97.5%~101.1%,87.5%~92.9%。该方法样品处理简单快捷,检出限低,准确度和精密度高,适合土壤中镉和总汞含量的测定。

关 键 词:土壤      电感耦合等离子质谱法

Determination of Cadmium and Total Mercury in Soil by ICP-MS
Wang Li,Zhang Xiaohong,Feng Yanan.Determination of Cadmium and Total Mercury in Soil by ICP-MS[J].Chemical Analysis And Meterage,2017,26(3):64-66.
Authors:Wang Li  Zhang Xiaohong  Feng Yanan
Abstract:A method of ICP-MS was established for the determination of cadmium and total mercury in soil. The sample was dissolved at temperature of 100℃ by hydrochloric acid and nitric acid, being dissolved and dilluted to constant volume, and determined by using supernatant fluid. The linear range of cadmium and mercury was 0.502-10.20 ng/g, 0.212-5.010 ng/g, respectively, the correlation coefficients (r2) were more than 0.999, the detection limits of cadmium and total mercury in soil were 0.021, 0.002 μg/g, respectively. The relative standard deviations of determination results were 1.99%, 5.57%(n=6), and the recoveries were 97.5%-101.1%, 87.5%-92.9% for calnium and total mercury, respectively. The method is simple and easy to process sample, with low detection limit,high accuracy and precision, and it is suitable for the determination of cadmium and total mercury content in soil.
Keywords:soil  cadmium  mercury  ICP-MS
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号