首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Monitoring of Methyldopa by Fast Fourier Transform Continuous Cyclic Voltammetry at Gold Microelectrode
作者姓名:NOROUZI Parviz  GANJALI Mohammad Reza  SHAHTAHERI Sayed Jamaleddin  DINARVAND Rasoul  HAMZEHPOOR Ali
作者单位:a Center of Excellence in Electrochemistry, Department of Chemistry, University of Tehran, Tehran, Iran ;b Endocrinology & Metabolism Research Center, Tehran University of Medical Science, Tehran, Iran ;c Environmental Research Center, School of Public Health, University of Tehran, Tehran, Iran ;d Medicinal Nanotechnology Research Center, University of Tehran, Tehran, Iran ;
摘    要:A continuous cyclic voltammetric study of methyldopa at gold micro electrode was carried out. The drug in phosphate buffer (pH 2.0) is adsorpted at 400 mV, giving rise to change in the current of well-defined oxidation peak of gold in the flow injection system. The proposed detection method has some of advantages, the greatest one of which are as follows: first, it is no more necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. Signal-to-noise ratio has significantly increased by application of discrete Fast Fourier transform (FFT) method, background subtraction and two-dimensional integration of the electrode response over a selected potential range and time window. Also in this work some parameters such as sweep rate, eluent pH, and accumulation time and potential were optimized. The linear concentration range was of 1.0×10-7—1.0×10-11 mol•L-1 (r=0.9975) with a limit of detection and quantitation 0.004 nmol•L-1 and 0.03 nmol•L-1, respectively. The method has the requisite accuracy, sensitivity, precision and selectivity to assay methyldopa in tablets. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the methyldopa were considered.

关 键 词:methyldopa    continuous  cyclic  voltammetry    Fourier  transform    micro-electrode
收稿时间:2008-7-2
修稿时间:2008-10-10

Monitoring of Methyldopa by Fast Fourier Transform Continuous Cyclic Voltammetry at Gold Microelectrode
NOROUZI Parviz,GANJALI Mohammad Reza,SHAHTAHERI Sayed Jamaleddin,DINARVAND Rasoul,HAMZEHPOOR Ali.Monitoring of Methyldopa by Fast Fourier Transform Continuous Cyclic Voltammetry at Gold Microelectrode[J].Chinese Journal of Chemistry,2009,27(4):732-738.
Authors:NOROUZI  Parviz  GANJALI  Mohammad Reza  SHAHTAHERI  Sayed Jamaleddin  DINARVAND  Rasoul  HAMZEHPOOR  Ali
Institution:1. Center of Excellence in Electrochemistry, Department of Chemistry, University of Tehran, Tehran, Iran;2. Endocrinology & Metabolism Research Center, Tehran University of Medical Science, Tehran, Iran;3. Environmental Research Center, School of Public Health, University of Tehran, Tehran, Iran;4. Medicinal Nanotechnology Research Center, University of Tehran, Tehran, Iran
Abstract:A continuous cyclic voltammetric study of methyldopa at gold micro electrode was carried out. The drug in phosphate buffer (pH 2.0) is adsorpted at 400 mV, giving rise to change in the current of well‐defined oxidation peak of gold in the flow injection system. The proposed detection method has some of advantages, the greatest one of which are as follows: first, it is no more necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. Signal‐to‐noise ratio has significantly increased by application of discrete Fast Fourier transform (FFT) method, background subtraction and two‐dimensional integration of the electrode response over a selected potential range and time window. Also in this work some parameters such as sweep rate, eluent pH, and accumulation time and potential were optimized. The linear concentration range was of 1.0×10?7?1.0×10?11 mol·L?1 (r=0.9975) with a limit of detection and quantitation 0.004 nmol·L?1 and 0.03 nmol·L?1, respectively. The method has the requisite accuracy, sensitivity, precision and selectivity to assay methyldopa in tablets. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the methyldopa were considered.
Keywords:methyldopa  continuous cyclic voltammetry  Fourier transform  micro‐electrode
本文献已被 万方数据 等数据库收录!
点击此处可从《中国化学》浏览原始摘要信息
点击此处可从《中国化学》下载免费的PDF全文