首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Trace analysis of antidepressants in environmental waters by molecularly imprinted polymer-based solid-phase extraction followed by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry
Authors:Kristof Demeestere  Mira Petrovi?  Meritxell Gros  Jo Dewulf  Herman Van Langenhove  Damià Barceló
Institution:1. Research Group EnVOC, Department of Organic Chemistry, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium
2. Department of Environmental Chemistry, IDAEA-CSIC, c/Jordi Girona 18-26, 08034, Barcelona, Spain
3. Institució Catalana de Recerca i Estudis Avan?ats (ICREA), Passeig Lluis Companys 23, 80010, Barcelona, Spain
4. Institut Català de Recerca de l’Aigua (ICRA), Parc Científici Tecnológic de la Universitat de Girona, c/Pic de Peguera, 15, 17003, Girona, Spain
Abstract:This paper presents the development, optimization, and validation of an innovative method to analyze trace concentrations of seven selected psychoactive pharmaceuticals in environmental waters. Hereby, the solid-phase extraction (SPE) potential of molecularly imprinted polymers (MIPs) in terms of extraction recovery, breakthrough, precision, and selectivity is studied for the first time. Instrumental analysis by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry allowed a rapid (run time = 7.5 min) and sensitive (instrumental detection limit ≤7 pg injected) quantification of the target analytes. A systematic optimization study revealed that, among the seven compounds of interest, mainly the selective serotonin reuptake inhibitors paroxetine, fluoxetine, and citalopram are selectively retained on the MIPs. Experiments performed in spiked river water, sewage treatment plant (STP) effluent and influent showed for these compounds extraction recoveries higher than 70%, breakthrough volumes up to 200 mL, method detection limits (MDL) as low as 0.5 ng/L, and good precision (exemplified by relative standard deviations better than 15%, n ≥ 3). Compared to the widely used hydrophilic–lipophilic balanced (HLB) polymers, the newly developed MIPs indicated to be more resistant toward matrix effects induced ion signal suppression particularly when dealing with relative dirty samples like STP influents. As a result of the better selectivity, the MDL obtained with the MIP-based SPE method was up to a factor of 7 lower compared to those obtained with a recently reported multi-residue HLB method. However, optimizing a HLB method in terms of selectivity, e.g., by introducing a stronger washing protocol, can significantly reduce its MDL up to values approximating those obtained with MIPs.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号